NEWARE offers charge/discharge battery testing systems ranging from μA signal cell applications up to 300kw packs.
Application:
1,Coincell,cylindrical,prismatic,&flat cell testing.
2,Basic cycling,electrochemical experiment,and advanced real-world simulations.
3,Battery packs and modules of all sizes.
4,Any battery chemistry including lithium,silicon,sulfur,nickel,&more.
Technical Specification:
BTS-5V20A | Battery Testing System |
Model: | BTS- | 5 | V | 20 | A | Material Code: | CT-4008 | -5V20A | - | NA | - |
|
Description | Product Specification |
AC Input | AC 220V±10% 50Hz |
Power | 1418 | W |
Resolution | AD: 16bit; DA: 16bit |
Impedance Input | ≥1MΩ |
Voltage | Measuring Range | 25mV~5V |
Discharge Min Voltage | 2.5V |
Accuracy | ± 0.1% of FS |
Stability | ± 0.1% of FS |
Current | Range | Charge: 100mA~20A Discharge: 100mA~20A |
Accuracy | ± 0.1% of FS |
Stability | ± 0.1% of FS |
Power | Output Power Per Channel | 100W |
Stability | ± 0.2% of FS |
Time | Rise Time | 20ms (10%FS~90%FS) |
StepTime | ≤ (365*24) hour/step | Time Format 00:00:00:000 (h:min:s:ms) |
Data Acquisition | Intervals | Time interval Δt: (100ms~60000s) |
Voltage interval ΔU: (10mV~5V) |
Current interval ΔI: (40mA~20A) |
Frequency | 10Hz |
Charge | Modes of Operation | CCC, CVC, CC & CVC, CPC |
End Conditions | Voltage, Current, Test Time, Capacity |
Discharge | Modes of Operation | CCD, CPD, CRD |
End Conditions | Voltage, Current, Test Time, Capacity |
Pulse | Charge | CCC |
Discharge | CCD |
Minimum Pulse Width | 500ms |
Automated Switch | Automated switch from charge to discharge for each pulse |
End Condition | Voltage, Test Time |
Cycle | Cycles | 65535 |
Steps | 254 |
Nested Function | Max three levels of loops |
Protective Function | Power-off data protection |
Off-line Operating |
User-defined safety (upper and lower) tolerance of current, voltage and delay time |
Reverse-connecting protection |
Channel Features | Independent pairs of closed loop for constant current source and constant voltage source |
Channels | Independent control |
Detection and Sampling | 4-wire Connecting |
Noise Density | <85dB |
Data Management | MYSQL Database |
Communication Means | TCP/IP Protocol |
Exports Formats | EXCEL, TXT, Graph |
Communication Interface | Ethernet Port |
Number of Channels Per Cabinet | 8 |
Operating Environment |
Description | Product Specification |
Operating Temperature | 0ºC~40ºC |
Storage Temperature | -10ºC~50ºC |
Operating Humidity | ≤70% RH |
Storage Humidity | ≤80% RH |
Warraty: 1 year
Delivery: 7days after deposit
Contact information:
Emily Zhang
zhanglibo at neware.com.cn